Optosky ATP5000 Series Deep Ultraviolet Spectrometers
Box
Optosky's ATP5000 series of miniature, high sensitivity spectrometers are particularly suited to low light level, ultraviolet (UV) sensitive applications such as fluorescence, DNA sequencing and Raman analysis.
Want to purchase this product?
Get in touch using one of the methods below
Model | Wavelength Range (nm) | Pixel Number | Integration time | Price |
---|---|---|---|---|
ATP5020P-DUV-VIS | 200-850 | 2048 x 64 | 10ms-15min | PoR |
ATP5020P-DUV-VIS-NIR Extended | 193-1008 | 2048 x 64 | 10ms-15min | PoR |
ATP5020P-DUV-VIS-IR | 200-1000 | 2048 x 64 | 10ms-15min | PoR |
ATP5020P-DUV | 200-400 | 2048 x 64 | 10ms-15min | PoR |
ATP5020P-NIR | 600-1000 | 2048 x 64 | 10ms-15min | PoR |
ATP5020P-IR | 800-1000 | 2048 x 64 | 10ms-15min | PoR |
ATP5040-IR | 800-1000 | 4096 | 1ms-80s | PoR |
ATP5040-NIR | 600-1000 | 4096 | 1ms-80s | PoR |
ATP5040-DUV-VIS-NIR | 200-1000 | 4096 | 1ms-80s | PoR |
ATP5040-DUV-VIS | 200-850 | 4096 | 1ms-80s | PoR |
ATP5040-DUV | 200-400 | 4096 | 1ms-80s | PoR |
ATP5040-DUV-VIS-IR Extended | 193-1008 | 4096 | 1ms-80s | PoR |
Summary Box
Optosky's ATP5000 series of miniature, high sensitivity spectrometers are particularly suited to low light level, ultraviolet (UV) sensitive applications such as fluorescence, DNA sequencing and Raman analysis.
Description:
The ATP5020/5040 miniature spectrometers feature back-thinned charge coupled device (CCD) area image sensors which offer high UV response, great signal-to-noise characteristics and wide dynamic range, making them especially suited to low light level applications.
The ATP5020P is a high-performance refridgerating micro-fiber spectrometer using a 2048x64 pixel cooled linear CCD. The CCD can work in a set constant temperature environment (up to 5oC), which greatly reduces the noise of the sensor and achieves excellent signal-to-noise ratio.
- Back-thinned CCD detector
- High UV sensitivity
- Optical resolution: 0.01-3nm (depending on slit)
- SNR: >8000:1
- Spectral coverage: 180-1100nm
- Integration time: 2ms-1300s
- ADC resolution: 18bit
- ADC sampling rate: 570kHz
Specifications:
Model | Wavelength Range (nm) | Detector Type | Entrance slits (µm) | Integration Time | Number of Pixels | Dark Noise | Optical Resolution | Dynamic Range | Signal to Noise Ratio | Scan rate |
ATP5020P-DUV-VIS-IR |
193-1008 | Cooled CCD model s10420+TEC or s11850 | 5, 10, 25, 50, 100 or 200 µm available | 10ms-15min | 2048 x 64 | 6 e-rms |
0.1-3 nm | 5000:1 | >600:1 | <100fps |
ATP5020P-DUV | 200-400 | Cooled CCD model s10420+TEC or s11850 | 5, 10, 25, 50, 100 or 200 µm available | 10ms-15min | 2048 x 64 | 6 e-rms | 0.1-3 nm | 5000:1 | >600:1 | <100fps |
ATP5020P-DUV-VIS | 200-850 | Cooled CCD model s10420+TEC or s11850 | 5, 10, 25, 50, 100 or 200 µm available | 10ms-15min | 2048 x 64 | 6 e-rms | 0.1-3 nm | 5000:1 | >600:1 | <100fps |
ATP5020P-DUV-VIS-NIR | 200-1000 | Cooled CCD model s10420+TEC or s11850 | 5, 10, 25, 50, 100 or 200 µm available | 10ms-15min | 2048 x 64 | 6 e-rms | 0.1-3 nm | 5000:1 | >600:1 | <100fps |
ATP5020P-NIR | 600-1000 | Cooled CCD model s10420+TEC or s11850 | 5, 10, 25, 50, 100 or 200 µm available | 10ms-15min | 2048 x 64 | 6 e-rms | 0.1-3 nm | 5000:1 | >600:1 | <100fps |
ATP5020P-IR | 800-1000 | Cooled CCD model s10420+TEC or s11850 | 5, 10, 25, 50, 100 or 200 µm available | 10ms-15min | 2048 x 64 | 6 e-rms | 0.1-3 nm | 5000:1 | >600:1 | <100fps |
ATP5040-DUV-VIS- IR | 193-1008 | s13496 +TEC | 5, 10, 25, 50, 100 or 200 µm available | 1ms-80s | 4096 | 0.4mVrms | 0.1-3 nm | 5000:1 | >600:1 | <1 kfps |
ATP5040-DUV | 200-400 | s13496 +TEC | 5, 10, 25, 50, 100 or 200 µm available | 1ms-80s | 4096 | 0.4mVrms | 0.1-3 nm | 5000:1 | >600:1 | <1 kfps |
ATP5040- DUV-VIS | 200-850 | s13496 +TEC | 5, 10, 25, 50, 100 or 200 µm available | 1ms-80s | 4096 | 0.4mVrms | 0.1-3 nm | 5000:1 | >600:1 | <1 kfps |
ATP5040-DUV-VIS-NIR | 200-1000 | s13496 +TEC | 5, 10, 25, 50, 100 or 200 µm available | 1ms-80s | 4096 | 0.4mVrms | 0.1-3 nm | 5000:1 | >600:1 | <1 kfps |
ATP5040-NIR | 600-1000 | s13496 +TEC | 5, 10, 25, 50, 100 or 200 µm available | 1ms-80s | 4096 | 0.4mVrms | 0.1-3 nm | 5000:1 | >600:1 | <1 kfps |
ATP5040-IR | 800-1000 | s13496 +TEC | 5, 10, 25, 50, 100 or 200 µm available | 1ms-80s | 4096 | 0.4mVrms | 0.1-3 nm | 5000:1 | >600:1 | <1 kfps |