Ocean Insight Flame UV-VIS-NIR Preconfigured Spectrometers with high thermal stability
Ocean Insight Spectrometers

Ocean Insight Flame UV-VIS-NIR Preconfigured Spectrometers with high thermal stability

Box

The Flame spectrometer is built using industry-leading manufacturing techniques that help deliver high thermal stability and low unit to unit variation — without compromising the flexibility and configurability that are the hallmark of Ocean Insight miniature spectrometers.
Regular price £2,624.00 £0.00
Model Wavelength Range (nm) Number of pixels Integration time Price Order
FLAME-S-UV-VIS 200-850 2048 1 ms – 65 seconds £2,733.00

FLAME-S-UV-VIS-ES 200-850Enhanced Sensitivity 2048 1 ms – 65 seconds £2,897.00

FLAME-S-VIS-NIR 350-1000 2048 1 ms – 65 seconds £2,624.00

FLAME-S-VIS-NIR-ES 350-1000Enhanced Sensitivity 2048 1 ms – 65 seconds £2,788.00

FLAME-S-XR1 200-1025 2048 1 ms – 65 seconds £3,105.00

FLAME-S-XR1-ES 200-1025Enhanced Sensitivity 2048 1 ms – 65 seconds £3,269.00

FLAME-S-RAD 200-850 2048  3.8 ms – 10 seconds £3,631.00

FLAME-T-UV-VIS 200-850 3648  3.8 ms – 10 seconds £2,733.00

FLAME-T-UV-VIS-ES 200-850Enhanced Sensitivity 3648  3.8 ms – 10 seconds £2,897.00

FLAME-T-VIS-NIR 350-1000 3648  3.8 ms – 10 seconds £2,624.00

FLAME-T-VIS-NIR-ES 350-1000Enhanced Sensitivity 3648  3.8 ms – 10 seconds £2,788.00

FLAME-T-XR1 200-1025 3648  3.8 ms – 10 seconds £3,105.00

FLAME-T-XR1-ES 200-1025Enhanced Sensitivity 3648  3.8 ms – 10 seconds £3,269.00

FLAME-NIR 950-1650 128 1 ms - 65 seconds £5,641.00

Summary Box

The Flame spectrometer is built using industry-leading manufacturing techniques that help deliver high thermal stability and low unit to unit variation — without compromising the flexibility and configurability that are the hallmark of Ocean Insight miniature spectrometers.

Description:

Whether you are an educator looking for an instrument to teach students the basic principles of spectroscopy, a research lab looking to make a breakthrough, or an engineer working to integrate a spectrometer into an OEM system, the Flame will provide you with the performance and features you need to make your UV-Vis spectroscopy application successful. New features such as interchangeable slits, indicator LEDs and simple device connectors deliver more freedom and less frustration. Take advantage of application-ready Flame systems for UV-Vis absorbance, fluorescence, Vis-NIR reflectance and NIR spectroscopy.

 

  • Modular— configurable to your application and needs within the wavelength range 190-1100 nm
  • Compatible— works with Ocean Insight light sources, accessories and software
  • Easy to use— plug and play via the micro USB connection
  • User interchangeable slit— allows you to vary the resolution and throughput of the spectrometer on demand
  • Indicator LEDs — indicator of power and data transfer status at all times
  • Compact and lightweight —89.1 mm x 63.3 mm x 34.4 mm and just 265 g

Specifications:

Model Wavelength Range (nm) Entrance slits (µm) Detector Type Number of Pixels Integration Time Signal To Noise Ratio Optical Resolution Dark Noise Dynamic Range
FLAME-S-UV-VIS 200-850 25µm (5, 10, 50, 100 or 200 µm also available) Sony ILX511B linear silicon CCD array 2048 1 ms – 65 seconds 250:1  ~0.1-10.0 nm 50  1300:1 
FLAME-S-UV-VIS-ES 200-850 25µm (5, 10, 50, 100 or 200 µm also available) Sony ILX511B linear silicon CCD array 2048 1 ms – 65 seconds 250:1  ~0.1-10.0 nm 50  1300:1 
FLAME-S-VIS-NIR 350-1000 25µm (5, 10, 50, 100 or 200 µm also available) Sony ILX511B linear silicon CCD array 2048 1 ms – 65 seconds 250:1  ~0.1-10.0 nm 50  1300:1 
FLAME-S-VIS-NIR-ES 350-1000 25µm (5, 10, 50, 100 or 200 µm also available) Sony ILX511B linear silicon CCD array 2048 1 ms – 65 seconds 250:1  ~0.1-10.0 nm 50  1300:1 
FLAME-S-XR1 200-1025 25µm (5, 10, 50, 100 or 200 µm also available) Sony ILX511B linear silicon CCD array 2048 1 ms – 65 seconds 250:1  ~0.1-10.0 nm 50  1300:1 
FLAME-S-XR1-ES 200-1025 25µm (5, 10, 50, 100 or 200 µm also available) Sony ILX511B linear silicon CCD array 2048 1 ms – 65 seconds 250:1  ~0.1-10.0 nm 50  1300:1 
FLAME-S-RAD 200-850 25µm (5, 10, 50, 100 or 200 µm also available) Sony ILX511B linear silicon CCD array 2048  3.8 ms – 10 seconds 250:1  ~0.1-10.0 nm 50  1300:1 
FLAME-T-UV-VIS 200-850 25µm (5, 10, 50, 100 or 200 µm also available) Toshiba TCD1304AP linear silicon CCD array 3648  3.8 ms – 10 seconds 300:1  ~0.1-10.0 nm 50  1300:1 
FLAME-T-UV-VIS-ES 200-850 25µm (5, 10, 50, 100 or 200 µm also available) Toshiba TCD1304AP linear silicon CCD array 3648  3.8 ms – 10 seconds 300:1  ~0.1-10.0 nm 50  1300:1 
FLAME-T-VIS-NIR 350-1000 25µm (5, 10, 50, 100 or 200 µm also available) Toshiba TCD1304AP linear silicon CCD array 3648  3.8 ms – 10 seconds 300:1  ~0.1-10.0 nm 50  1300:1 
FLAME-T-VIS-NIR-ES 350-1000 25µm (5, 10, 50, 100 or 200 µm also available) Toshiba TCD1304AP linear silicon CCD array 3648  3.8 ms – 10 seconds 300:1  ~0.1-10.0 nm 50  1300:1 
FLAME-T-XR1 200-1025 25µm (5, 10, 50, 100 or 200 µm also available) Toshiba TCD1304AP linear silicon CCD array 3648  3.8 ms – 10 seconds 300:1  ~0.1-10.0 nm 50  1300:1 
FLAME-T-XR1-ES 200-1025 25µm (5, 10, 50, 100 or 200 µm also available) Toshiba TCD1304AP linear silicon CCD array 3648  3.8 ms – 10 seconds 300:1  ~0.1-10.0 nm 50  1300:1 
FLAME-NIR 950-1650 25µm (5, 10, 50, 100 or 200 µm also available) Hamamatsu G8160-03 128 1 ms → 65 seconds 6000:1  ~10 nm   6000:01:00

 